| Submitted | Field | Original | Note / Status | |
|---|---|---|---|---|
No corrections yet. Use the flag at the end of a row to report an issue. | ||||
| Submitted | Field | Original | Note / Status | |
|---|---|---|---|---|
No corrections yet. Use the flag at the end of a row to report an issue. | ||||
Automatic mm / inch conversion · Core engineering specifications
| Overall dimensions (upright position) | 680 x 800 x 1150 mm | |
|---|---|---|
| Seat height from floor | 450 mm | |
| Seat cushion size | 500 x 480 x 80 mm | |
| Backrest height (upright) | 700 mm | |
| Headrest cushion size | 380 x 120 x 60 mm | |
| Armrest height from seat | 220 mm | |
| Extended leg rest length | 400 mm | |
| IV pole total height | 1700 mm | |
| Side storage basket dimensions | 300 x 150 x 180 mm | |
| Knee clearance under seat | 180 mm | |
| Leg rest foot bar width | 420 mm | |
| Finished Seat Cushion Thickness | 90 mm | |
| Backrest Padding Thickness | 70 mm | |
| Lumbar Support Zone Height | 240 mm | |
| Clear Width Between Armrests | 540 mm |
Net weight / load capacity / users / durability
| Net weight | 28 kg | |
|---|---|---|
| Maximum user weight capacity | 150 kg | |
| Foam density (seat and back) | 45 kg/m³ | |
| Upholstery abrasion resistance | 100000 cycles | |
| IV pole vertical load capacity | 5 kg | |
| Backrest recline mechanism cycle life | 12000 cycles | |
| Recommended single session use duration | 8 hours | |
| Seat Foam Density / Rebound Reference | 45 kg/m³ / 65% | |
| Back Foam Density Reference | 38 kg/m³ | |
| Upholstery Thickness / Abrasion Reference | 1.4 mm / 50000 cycles |
Core acceptance fields · Panels / hardware / frame / upholstery
| Primary load frame | 1.5mm thick powder-coated cold-rolled steel tubing | |
|---|---|---|
| Upholstery cover | 0.8mm thick medical-grade antibacterial faux leather | |
| Seat and back padding | High-density polyurethane foam | |
| Armrest pads | Padded faux leather over steel arm support | |
| IV pole construction | Stainless steel telescoping tubing with two chrome-plated IV hooks | |
| Side storage basket | 5mm diameter chrome-plated steel wire mesh | |
| Flip-out leg rest frame | Powder-coated steel with hinge mechanism | |
| Foot pads | Non-slip rubber floor glides | |
| Recline mechanism hardware | Zinc-plated steel hinges and locking bolts | |
| Seat Internal Support Board Thickness | 14 mm bent plywood or equivalent support board | |
| Backrest Internal Frame Thickness | 14 mm bent plywood/composite reinforced frame | |
| Gas-lift Engineering Specification | Recommended Class 4; outer tube 50 mm; stroke 100 mm |
Adjustment / rotation / tilt / mobility / storage features
| Backrest recline adjustment | Multi-position manual recline with locking lever, adjusts from 95 degree upright to 135 degree reclined position | |
|---|---|---|
| Flip-out leg rest operation | Manual swing-out leg rest that folds flush under seat when not in use, locks in horizontal extended position for leg elevation | |
| IV pole height adjustment | Telescoping stainless steel pole with twist-lock height adjustment, total adjustability range of 600mm | |
| Fixed position stability | Four-point floor contact with rubber glides, no casters for stable fixed placement in infusion bays | |
| Easy-clean surface design | Seam stitched upholstery with no sharp crevices, compatible with standard hospital disinfectant wipes for infection control | |
| Headrest support | Integrated fixed padded headrest at top of backrest, provides cervical neck support in both upright and reclined positions | |
| Transfer accessibility | Wide open front seat access, 220mm high armrests that support patient weight during standing or wheelchair transfer | |
| Backrest maximum recline angle | 135 degrees | |
| Recline Angle / Lock Reference | 125° with 3 suggested lock positions | |
| Tilt Tension User-weight Range | Reference adjustment coverage 120 kg | |
| Rotation / Mobility Configuration | 360° swivel with 5-caster multidirectional movement |
Verified carton / gross weight / assembly / loading data
| Number of shipping cartons | 1 pc | |
|---|---|---|
| Shipping carton dimensions | 800 x 700 x 650 mm | |
| Gross shipping weight | 33 kg | |
| Shipping volume per unit | 0.364 CBM | |
| On-site assembly time | 20 minutes | |
| 20ft GP container loading quantity | 90 units | |
| 40ft HQ container loading quantity | 210 units | |
| Packaging protection | Five-layer corrugated carton with EPS foam corner bracing and plastic wrap | |
| Reference Package Count | 1 set / 2 cartons | |
| Reference Assembly Time | 40 minutes per set |
Recommended spaces / users / usage modes
| Hospital outpatient infusion rooms | Fixed placement in individual infusion bays, provides comfortable long-duration seating for patients receiving IV therapy, with integrated IV pole for clinical workflow efficiency | |
|---|---|---|
| Community health clinics and vaccination centers | Durable easy-clean seating suitable for high daily patient volume, supports patient positioning during treatments, injections or short observation periods | |
| Emergency department observation areas | Compact footprint fits in tight observation bays, stable fixed frame ensures patient safety during post-treatment monitoring, IV pole eliminates need for separate stand units | |
| Private medical practitioner offices | Professional clinical appearance suitable for consulting rooms, treatment rooms, or minor procedure areas, easy to disinfect between patient visits | |
| Blood donation centers | Reclined position supports donor comfort during blood collection, leg rest helps prevent vasovagal reactions by enabling leg elevation, armrests provide stable surface for phlebotomy access | |
| Recommended Matching Desk Size | 2.4 m executive desk | |
| Reference Daily Use Duration | 8 hours/day; confirm by ergonomic testing |
EU Market Access Requirements* EN Standards
| Medical device furniture safety | EN 60601:2006+A12:2014 | |
|---|---|---|
| Office and institutional seating stability | EN 16139:2013 | |
| Medical surface disinfectant compatibility | EN 14476:2013+A2:2019 |
US and Canada office-furniture standards
| Seating static load testing | ANSI/BIFMA X2017 |
|---|
Standards applicable to China-market projects
| Medical furniture safety requirement | GB 9706.1 | |
|---|---|---|
| Furniture mechanical safety standard | GB/T 3324 | |
| Upholstered furniture fire safety | GB 20286 |
This product must meet the following technical requirements: 1. Medical furniture safety requirement: GB 9706.1; 2. Furniture mechanical safety standard: GB/T 3324; 3. Upholstered furniture fire safety: GB 20286; Final delivery parameters, test reports, and acceptance criteria are subject to the purchase contract.
Export data is generated from the current published product record.
Directly download an English report in metric or imperial units.
Download all product information and parameter modules in English.
English title, specifications, materials, standards and purchasing fields.
Prepare customs description, material, usage, dimensions and declaration elements.
Open Export Tool